C&G 2382 (BS7671 18th Edition) Part 1 Practice Questions – Set 1
Results
Congratulations – You Passed! 🎉
You’ve got a good understanding of the City & Guilds 2382 Level 3 Award in the Requirements for Electrical Installations and the Wiring Regulations.
Passing this quiz is a great indication that you’re on the right track. Whether you’re brushing up on your knowledge or preparing for a qualification, you’ve clearly got a solid grasp of the subject.
Want to build on your knowledge even further?
Find out more about our electrical courses here:
https://www.pragmatic-consulting.co.uk/training-courses/electrical/
Not Quite This Time
Not quite a passing score this time, but don’t let that put you off.
The Wiring Regulations can be challenging, and this quiz is designed to test your understanding across a range of topics. Every attempt helps you identify areas where you can improve.
Why not review the topics you struggled with and give the quiz another go?
Looking to strengthen your knowledge and boost your confidence?
Our City & Guilds 2382 training course is designed to help you understand the Wiring Regulations and prepare for the qualification.
Find out more about our electrical courses here:
https://www.pragmatic-consulting.co.uk/training-courses/electrical/
#1. BS 7671 does not apply to
#2. Which one of the following parts of BS 7671 contains particular requirements relating to protection for safety
#3. Which of the following installations is excluded from the scope of BS 7671?
#4. It should be confirmed by the designer or specifier that any addition or alteration to an existing installation will
#5. Which of the following supply characteristics would need to be ascertained and determined for an electrical installation?
#6. Which of the following is not a characteristic of the supply?
#7. An electrical installation with a nominal voltage of 400 V AC between conductors would be defined as
#8. A device intended to make dead for reasons of safety all or a discrete section of the electrical installation by separating the electrical installation, or section thereof, from every source of electrical energy is defined as providing
#9. The conductor which connects together the MET and all exposed conductive parts is the
#10. The earthing arrangement which incorporates a separate path to earth is
#11. The electrical system in which there is a protective neutral bonding connection is
#12. Which one of the following can ensure safe inspection, testing and maintenance for all electrical installations?
#13. Which one of the following should consider measures to reduce the effects of EMI in an installation with regard to electromagnetic compatibility?
#14. Where particular risks of fire exist in an area of high-density, crowded occupation with difficult conditions of evacuation, the most appropriate external influence code would be
#15. Which of the following is not considered as a potential source of electromagnetic disturbance?
#16. Where measures are taken against electromagnetic disturbances, what are the minimum nominal dimensions of a flat cross-section bonding ring network conductor?
#17. Which of the following can provide protection against overload?
#18. Which of the following is a method of fault protection?
#19. A standard shaver supply unit socket-outlet, complaint to BS EN 61558-2-5, is an example of protection being provided by
#20. If a circuit forming part of a 230 V TT system has protection being provided by an RCD with a rated residual operating current of 100 mA, the maximum acceptable earth fault loop impedance value, Zs, would be