“The trainer kept the course flowing and got everyone involved & kept it interesting.”
18th edition quiz
Home > News & Blogs > C&G 2382 (BS7671 18th Edition) Part 5 Practice Questions – Set 1

C&G 2382 (BS7671 18th Edition) Part 5 Practice Questions – Set 1

 

Results

Congratulations – You Passed! 🎉

You’ve got a good understanding of the City & Guilds 2382 Level 3 Award in the Requirements for Electrical Installations and the Wiring Regulations.

Passing this quiz is a great indication that you’re on the right track. Whether you’re brushing up on your knowledge or preparing for a qualification, you’ve clearly got a solid grasp of the subject.

Want to build on your knowledge even further?

Find out more about our electrical courses here:
https://www.pragmatic-consulting.co.uk/training-courses/electrical/

Not Quite This Time

Not quite a passing score this time, but don’t let that put you off.

The Wiring Regulations can be challenging, and this quiz is designed to test your understanding across a range of topics. Every attempt helps you identify areas where you can improve.

Why not review the topics you struggled with and give the quiz another go?

Looking to strengthen your knowledge and boost your confidence?

Our City & Guilds 2382 training course is designed to help you understand the Wiring Regulations and prepare for the qualification.

Find out more about our electrical courses here:
https://www.pragmatic-consulting.co.uk/training-courses/electrical/

#1. Where the main earth terminal is separate from main switchgear, a warning label should be fixed in a visible position at or near with the wording

#2. Where an RCD is present within an installation, a notice shall be fixed in a prominent position at or near the device, advising the user to perform a functional test of the functionality at least once every

#3. A non-flame propagating wiring system having a maximum internal cross-sectional area of 710 mm2

#4. To which depth should cables that are placed directly in the ground be buried at?

#5. Which of the following types of SPD is the most appropriate for installation at the origin of an electrical installation to provide protection against direct lightning strikes?

#6. Which one of the following can be used as a device for emergency switching off?

#7. Where practical, the connection of the main protective equipotential bonding to the gas services in a building should be made within

#8. The minimum cross-sectional area of a supplementary bonding conductor connecting two extraneous-conductive-parts, with mechanical protection, should be

#9. A firefighter’s switch should comply with which one of the following requirements?

#10. Where an RCD is installed upstream of an RCM, it recommended that the RCM be set to a residual actuating current no higher than

#11. Which document must be issued, following a periodic inspection and testing of an electrical installation, to the person ordering the inspection and testing?

#12. The test voltage to be used for an insulation resistance test between the live and protective conductors of a 400 V circuit is

#13. Upon completion of initial verification, an Electrical Installation Certificate must be completed by

#14. A check of phase sequence shall be verified on

#15. Electrical equipment installed in Zones 1 and 2 of a bathroom, where water jets are not utilised for cleaning purposes, must have a minimum degree of protection of

#16. Within Zones 0 and 1 of a swimming pool, a protective provision against electric shock should be by means of

#17. Which one of the following is not classified as an outdoor lighting installation?

#18. Which one of the following protective measures shall be used for switches, not incorporated in equipment, in Zone 1 of a bathroom?

#19. To provide protection against external influences, outdoor lighting installations must be provided with a minimum degree of protection of

#20. In a location containing a bath or shower, the protective measure of earth-free local equipotential bonding is

#21. Which mechanical protection code should equipment on a pontoon in a marina, that is subject to impact to level AG2, have?

#22. To acknowledge the risk of medium severity of mechanical protection, equipment within zones 0 and 1 of a fountain should be classified as

#23. What is the minimum height of overhead conductors on caravan sites, when installed in areas subject to vehicle movement?

#24. Which one of the following is not a type of PEI?

#25. Which one of the following is the correct grouping rating factor for six circuits bunched on a surface?

#26. If an external influence has a general category code of B, which of the following does this code indicate?

#27. In which appendix of BS 7671 can details on ring and radial final circuit arrangements be located?

#28. The derating factor to be applied for a cable surrounded by thermal insulation for a length in excess of 500 mm is

#29. Installed electrical equipment is being installed that must be capable of being immersed in water and be able to withstand a temperature range of -5 °C to +40°C Which are the most appropriate external influence codes for this item of equipment?

#30. In which appendix of BS 7671 can details on escape routes and fire protection be located?

Previous
Finish

This website uses cookies

We use cookies to personalise content, provide social media features, and analyse our traffic. We also share information about your use of our site with our analytics partners. You can change your preferences at any time. For more information, please see our Privacy Policy and Cookie Policy. Privacy Policy Cookie Policy